  Products > Traffic > Signal Monitors
 

NEMA TS-2 Signal Monitors

MMU-16LE SmartMonitor™ LCD Series
The MMU-16LE series Malfunction Management Unit (MMU) exceeds all the requirements set forth in the NEMA Standard TS2-2003, Part 4. The model MMU-16LE includes two large area Liquid Crystal Displays (LCD) for a continuous Full Intersection display. A separate graphical LCD provides a menu driven interface to status, signal voltages, configuration, event logs, and the integrated context sensitive Help System. The built-in Setup Wizard ensures that the enhanced monitor programming is done quickly and accurately, even by a novice. The industry first Diagnostic Wizard automatically pinpoints malfunctioning signals and offers trouble shooting advice. An EIA232 port or Ethernet port is used to communicate with a Personal Computer using field proven EDI ECcom™ software. Monitor status, event logs, and Signal Sequence History logs are stored in nonvolatile memory for diagnostic and archival purposes. Four modes of Flashing Yellow Arrow PPLT support are provided.

Access the MMU-16LEip SmartMonitor remotely with an Ethernet 10/100Mbps WAN capability. Read more...

Use the MMU-16LE SmartMonitor with a TS-2 Type 2 Controller Unit in your Nema TS-1 cabinet with no cabinet wiring changes. Read more...

Use the MMU-16LE SmartMonitor with Flashing Yellow Arrow operation in your Nema TS-1 or TS-2 cabinet . Read more...

MMU-16LE 12/16 channel with EIA-232 Port
MMU-16LEip 12/16 channel with Ethernet Port

MMU-16E Series
The MMU-16E series Malfunction Management Units (MMU) exceed all the requirements set forth in the NEMA Standard TS2-2003 , Part 4 (TS2-1992 has been revised!). These units are intended to provide basic conflict and voltage monitoring for NEMA TS-2 traffic controller assemblies while maintaining downward compatibility with NEMA TS-1 assemblies. The model MMU-16E includes a RYG Full Intersection display along with an RS232 port which is used to communicate with a Personal Computer using EDI ECcom™ software. Monitor status, event logs, and Signal Sequence History logs are stored in nonvolatile memory for diagnostic and archival purposes.

MMU-16E 12/16 channel with EIA-232 Port


NEMA TS-1 Signal Monitors

MMU-16LE SmartMonitor™ LCD Series
The MMU-16LE SmartMonitor series Malfunction Management Unit (MMU) is compatible with 12-channel Nema TS1 cabinets by providing the Type 12 mode. The SmartMonitor includes two large area Liquid Crystal Displays (LCD) for a continuous Full Intersection display. A separate graphical LCD provides a menu driven interface to status, signal voltages, configuration, event logs, and the integrated context sensitive Help System. The built-in Setup Wizard ensures that the enhanced monitor programming is done quickly and accurately, even by a novice. The industry first Diagnostic Wizard automatically pinpoints malfunctioning signals and offers trouble shooting advice. An EIA232 port or Ethernet port is used to communicate with a Personal Computer using field proven EDI ECcom™ software. Monitor status, event logs, and Signal Sequence History logs are stored in nonvolatile memory for diagnostic and archival purposes. Four modes of Flashing Yellow Arrow PPLT support are provided.

Access the MMU-16LEip SmartMonitor remotely with an Ethernet 10/100Mbps WAN capability. Read more...

Use the MMU-16LE SmartMonitor with a TS-2 Type 2 Controller Unit in your Nema TS-1 cabinet with no cabinet wiring changes. Read more...

Use the MMU-16LE SmartMonitor with Flashing Yellow Arrow operation in your Nema TS-1 or TS-2 cabinet . Read more...

MMU-16LE 12/16 channel with EIA-232 Port
MMU-16LEip 12/16 channel with Ethernet Port

SSM-LE Series
The SSM-LE series Signal Monitors exceed all the requirements set forth in the NEMA Standard TS-1-1994, Part 6. These units are intended to provide enhanced conflict and voltage monitoring for traffic controller assemblies with additional capabilities for broader fault coverage and diagnostic troubleshooting. The SSM-6LE and SSM-12LE units include a Full Intersection Liquid Crystal display (LCD) along with an RS232 port which is used to communicate with a Personal Computer using EDI ECcom™ software. Monitor status, event logs, and Signal Sequence History logs are stored in nonvolatile memory for diagnostic and archival purposes. Two modes of Flashing Yellow Arrow PPLT support are provided.

SSM-6LE 6 channel with EIA-232 Port
SSM-6LEip 6 channel with Ethernet Port
SSM-12LE 12 channel with EIA-232 Port
SSM-12LEip 12 channel with Ethernet Port
SSM-18LEPR 18 channel (not ECcom™ compatible)

NSM-E Series
The NSM-E series Signal Monitors exceed all the requirements set forth in the NEMA Standard TS-1-1994, Part 6. These units are intended to provide enhanced conflict and voltage monitoring for traffic controller assemblies with additional capabilities of Dual Indication and Clearance monitoring for broader fault coverage. A full intersection display and event logging capabilities on the six and twelve channel units make trouble shooting more effective.

SSM-3E 3 channel
NSM-6E 6 channel
NSM-12E 12 channel

NSM Series
The NSM series Signal Monitors exceed all the requirements set forth in the NEMA Standard TS-1-1994, Part 6. These units are intended to provide basic conflict and voltage monitoring forsmall two phase traffic controller assemblies.

NSM-3 3 channel



Type 170/179/2070 Signal Monitors

2010 Series Signal Monitors

2010ECL Series
The model 2010ECL is a 210ECL monitor configured for operation with a 2070 Controller Unit. It provides all the features of the 210ECL model as well as minimum flash capabilities for 2070 boot capability. The 2010ECL series monitor is compatible with 170, 179 and 2070 Controller Units. It is a recommended replacement for the 210E and 210ECL monitor in new installations using 170 or 2070 Controller Units. Two modes of Flashing Yellow Arrow PPLT support are provided. The model 2010ECLip provides a 10/100 Mbps Ethernet port.

2010ECL 16 channel with EIA-232 Port
2010ECLip 16 channel with Ethernet Port

2018ECL Series
The model 2018ECL is a 2010ECL monitor that provides 18 channels of monitoring. It provides all the features of the 210ECL model as well as minimum flash capabilities for 2070 boot capability. The 2018ECL series monitor is compatible with 170, 179 and 2070 Controller Units. It is a recommended replacement for the 210E and 210ECL monitor in new installations using 170 or 2070 Controller Units. Two modes of Flashing Yellow Arrow PPLT support are provided. The model 2018ECLip provides a 10/100 Mbps Ethernet port.

2018ECL 18 channel with EIA-232 Port
2018ECLip 18 channel with Ethernet Port

2018KCL Series
The model 2018KCL is an 18 channel version of the 2010ECL monitor. A removable Datakey memory device contains all the monitor set-up information and completely eliminates the need for a diode Program Card, soldered jumpers and DIP switches. Two modes of Flashing Yellow Arrow PPLT support are provided. The model 2018KCLip provides a 10/100 Mbps Ethernet port.

2018KCL 18 channel with EIA-232 Port
2018KCLip 18 channel with Ethernet Port

2010 Series
The model 2010 is a 210E monitor configured for operation with a 2070 Controller Unit. It provides all the features of the 210E model as well as minimum flash capabilities for 2070 boot capability. The 2010 series monitor is compatible with 170, 179 and 2070 Controller Units. It is a recommended replacement for the 210E monitor in new installations using 170 or 2070 Controller Units. Two modes of Flashing Yellow Arrow PPLT support are provided.

210 Series Signal Monitors

210ECL Series
The model 210ECL includes the functions of the 210E unit and adds a RYG Full Intersection display along with an RS232 port which is used to communicate with the Controller Unit operational software or a Personal Computer using EDI ECcom™ software. Monitor status, event logs, and Signal Sequence History logs are stored in nonvolatile memory for diagnostic and archival purposes.
210ECL

210E Series
The model 210E meets all the requirements set forth in the Caltrans Traffic Signal Control Specifications and provides the enhanced functions of Red signal monitoring, Dual Indication monitoring and Clearance monitoring.
210E

210C Series
The model 210C meets all the requirements set forth in the Caltrans Traffic Signal Control Specifications. These units are intended to provide basic conflict and voltage monitoring for Type 170/179 traffic controller assemblies.
210C Caltrans QPL listed
210-NY NYSDOT QPL listed


ITS Cabinet Signal Monitors

CMU-212 Series
The EDI CMU-212 Cabinet Monitor Unit is intended to operate with the AMU-214 Auxiliary Monitor Unit to form a compact and modular cabinet malfunction management system for the ITS Cabinet. The CMU-212 functions as the main cabinet fault monitoring component. It offers the broadest fault coverage of any monitoring system and incorporates full event logging and status reporting, providing the signal technician with powerful monitoring and trouble-shooting tools to ensure that cabinet malfunctions are detected, diagnosed, and repaired with confidence.

The CMU-212 meets all requirements of the ASHTO/ITE/NEMA Intelligent Transportation System (ITS) Standard Specification for Roadside Cabinets Version 01.02.15, as well as the Caltrans TEES, August 2002 requirements.
CMU-212 32 channel Monitor Unit

AMU-214 Series
The EDI AMU-214 Auxiliary Monitor Unit is intended to operate with the CMU-212 Cabinet Monitor Unit to form a compact and modular cabinet malfunction management system for the ITS Cabinet. The AMU-214 provides the voltage and current data acquisition function of the cabinet monitoring system. Up to four AMU-214 units can be installed in ten different cabinet configurations with each CMU-212.

The AMU-214 meets all requirements of the ASHTO/ITE/NEMA Intelligent Transportation System (ITS) Standard Specification for Roadside Cabinets Version 01.02.15, as well as the Caltrans TEES, August 2002 requirements.
AMU-214 Dual mode 6 channel and 14 channel

MonitorKey™ Programming Tool
The EDI MonitorKey™ CMU Data Key Programming Tool provides the programming interface between a Personal Computer and the Data Key used to store configuration parameters in the CMU-212. The compact tool connects to a serial port of the PC and uses the MonitorKey™ Windows based software to read, write, and verify the contents of the Data Key. Software Wizards are provided to simplify the initial setup of the parameter database and check for consistency errors.